journal6 ›› 2002, Vol. 23 ›› Issue (2): 34-37.

• Key disciplines • Previous Articles     Next Articles

Treatment of the Electrolytic Mangan Wastewater byIron Chipping Microelectrolysis

  

  1. (1.Department of Chemistry,Jishou University, Jishou 416000,Hunan China;2.Research Institute of Environmental Protection of Xiangxi,Jishou 416000,Hunan China)
  • Online:2002-06-15 Published:2013-01-05

Abstract: The electrolytic mangan wastewater was processed by iron chipping.The factors of iron chipping amount, reaction time and the influence of wastewater pH on the purgation ratio of Cr6+,Mn2+ were investigated. The results show that under usual temperature when amount of iron chipping is 15%, wastewater pH is 4.00, reaction time is 120 min, Cr6+,Mn2+ and total chromium purgation ratio were 99.7% and 99.2%.when it was used to practice the treatment electrolytic mangan wastewater, purgation ratio of Cr6+,Mn2+ was 99.45% and 95.53%.

Key words: iron chipping, microelectrolysis, wastewater