摘要:
用ICP-AES基体匹配法测定了高导电铜中Ni,Be,Mg,Co和Si等微量元素含量,同时对所测元素相对不确定度进行了考察.发现以质量比计,元素Ni,Mg,Be,Co,Si的含量分别为2.13,0.088,0,0,0.22 mg/kg;相对不确定度主要由测量精密度和回收率2个因素决定.
关键词: ICP-AES法, 高导电铜, 基体匹配, 不确定度
Abstract:
The ICP-AES matrix matching method has been applied to determine the trace elements Ni,Be,Co,and Si in high conductivity copper,and the uncertainty of those elements has been analyzed.The results showed that the mass ratios of those elements were:Ni 2.13 mg/kg,Mg 0.088 mg/kg,Be 0 mg/kg,Co 0 mg/kg,Si 0.22 mg/kg and the main factors which determine the uncertainty were the measurement repeatability and recovery rate.
Key words: ICP-AES, high conductivity copper, matrix matching, uncertainty
刘邦夫. ICP-AES基体匹配法测定高导电铜中的微量元素[J]. 吉首大学学报(自然科学版), DOI: 10.13438/j.cnki.jdzk.2018.04.015.
LIU Bangfu. Determination of Trace Elements in High ConductivityCopper by Matrix Matching of ICP-AES[J]. Journal of Jishou University(Natural Sciences Edition), DOI: 10.13438/j.cnki.jdzk.2018.04.015.
0 / / 推荐
导出引用管理器 EndNote|Ris|BibTeX
链接本文: https://zkxb.jsu.edu.cn/CN/10.13438/j.cnki.jdzk.2018.04.015
https://zkxb.jsu.edu.cn/CN/Y2018/V39/I4/74
[1] 周晨.高强度高导电铜及铜合金的研究[J].新材料产业,2015(1):64-66. [2] 曹海波.ICP-AES法测定铝-锡-锆-钼-铬合金中七种元素[J].世界钢铁,2014,14(5):69-72. [3] 刘爱坤.ICP-AES法测定金属锰中硅、磷、铁、铜和镍[J].现代科学仪器,2010,6(3):114-116. [4] 全国物理化学计量技术委员会.JJF 1135—2005 化学分析测量不确定度评定[S].国家质量监督检验检疫总局,2005-09-05. [5] 徐民,郝吉升,刘鸿.如何在化学分析中正确使用回收率等质量控制方法[J].食品安全导刊,2015(15):99-100.