journal6 ›› 2005, Vol. 26 ›› Issue (2): 120-122.

• 科研简报 • 上一篇    下一篇

对输电线击杆率的探讨

  

  1. (1.西华大学,四川 成都 610039;2.北京铁道学院,北京100044)
  • 出版日期:2005-04-15 发布日期:2012-09-22
  • 作者简介:颜怀梁(1929-),四川省开江人,西华大学教授,主要从事高电压技术、数理统计、理论电工等研究.

Discussion on Rate of Lightning Striking Against Poles of Transmission Lines

  1. (1.Xihua University,Chengdu 610039,Sichuan China;2.Beijing Railway Institute,Beijing 100044,China)
  • Online:2005-04-15 Published:2012-09-22

摘要:输电线路的击杆率不仅与地形、杆塔高度、结构有关,而且与雷电流的幅值和概率有关,直接影响到线路雷击跳闸率计算.比照规程推荐的击杆率,应用电气几何模型原理,探讨了线路平均击杆率.

关键词: 输电线, 击杆率, 击距

Abstract: For transmission lines,the rate of lightning striking against poles directly affects the calculation of lightning trip-out rate.The former has not only relations to the topographic features,height and structure of poles but also to the amplitude and probability of lightning current.According to the rate recommended by “code”,the mean rate of lightning striking against poles of transmission lines is discussed with an electrogeometric model.

Key words: power transmission lines, lightning striking rate against poles, striking distance